Target Depth Display and Relay Output on EDM Digital Readouts

By zh-easson November 23rd, 2026 0 views

Introduction: Between the depth number on an EDM readout and the machine actually stopping sits a two-part path, and knowing which part does what makes a relay specification much easier to read.

An operator sets a target depth, watches the Z value climb as the electrode feeds down, and expects the machine to stop when that number is reached. Two separate things happen on the way there. The readout measures and compares, the relay output switches a circuit, and the machine decides what that switch means. Mixing those three up is where most confusion starts, especially when a feature line compresses the whole chain into a few words. This explanation follows the signal from scale to screen and then from screen to machine control, and it marks the points where the answer depends on the individual machine rather than on the readout.

Target Depth Display Belongs to the Readout Layer

A linear scale on the Z axis sends A/B (TTL) pulses to the readout; the readout counts them, applies its scaling, and puts a position value on the screen. Target depth joins that calculation as an entered number. From then on the readout keeps comparing live position against the target and, in the EDM setup described for the Easson ES8A, also keeps track of the deepest position the electrode has reached. In the working pattern the product information describes, X and Y stay put while Z moves up and down, so the depth value is the number the operator watches. All of this is display work: value in, comparison made, value shown. Keeping that inside the readout layer matters because the display is passive with respect to the machine. A target depth on screen does not move the electrode, speed the feed, or stop anything; it gives the operator a shared reference for where the cut should end and where it stands right now. The same reasoning explains why a three-axis readout with three linear encoder inputs, mm/Inch switching and ABS/INC display modes can be described entirely in display terms — these are ways of expressing and comparing position. Whether anything outside the readout reacts comes down to the output stage, which is a different link in the chain and follows different rules. A useful habit follows from this. Before a cut begins, the operator can check the target value itself against the job, because a wrong target produces a perfectly correct display of the wrong destination. The readout will faithfully compare position with whatever number it was given, which is exactly why the entered value deserves a second look while the machine is still clear.

Relay Output Connects the Readout to a Machine Control Circuit

The relay output is where the readout stops talking to the operator and starts talking to the machine. Inside the readout, an output driver energizes a relay coil, and the coil pulls a set of contacts from their resting state into their active state. Those contacts sit in a different circuit — the machine's control circuit — and changing their state is the entire message the readout sends. The full path reads: scale pulses into the counter, counter into comparison with the target, comparison into the output driver, driver into the relay coil, coil into contact state, contact state into the machine's input. Everything before the last step is logic; the last step is a switch, and a switch only carries as much meaning as the circuit around it gives it. The published product information for the ES8A describes the target depth relay with pin 6 and 7 normally open, changing to closed when activated, and pin 6 and 8 normally closed, changing to open when activated. Pin 6 appears in both pairs, which makes it the shared common terminal: the readout offers one normally open pair and one normally closed pair on the same common, and the installer chooses whichever suits the machine input. What a short feature line rarely carries is the electrical detail — coil data, contact rating, switching delay, exact trigger condition. Those values usually live in the manual, and they are the numbers that decide whether a given contact can switch a particular stop circuit. That is why a spec sheet from an EDM digital readout manufacturer tells you a switching function exists, while the machine documentation tells you whether it can be used.

1. Normally Open and Normally Closed Contacts Serve Different Switching Roles

Normally open and normally closed describe what a contact does while the relay is at rest. A normally open contact sits open and closes when the coil is energized, while a normally closed contact sits closed and opens when the coil is energized. Because the ES8A pairs share pin 6, the two are complementary: as one closes, the other opens. On an EDM stop circuit that distinction decides the wiring. If the machine's stop input expects a closed loop that opens to trigger a stop, the normally closed pair matches that logic. If it expects a circuit that closes to signal a stop, the normally open pair matches. The readout supplies both; the machine's input decides which one is correct.

2. Safety Rated Control Requires More Than a Relay Contact

A relay contact is a functional switch, and the arrangement around it — not the contact on its own — sets how much protection the setup provides. Safety-rated control normally involves redundant channels, monitored contacts, defined performance levels and documented validation, and the published description of this output is a stop aid for EDM work rather than a claim of that kind. The practical reading stays simple: pick the contact pair that matches the machine, use the contact inside its rating, and leave the wiring and assessment of the whole installation to someone competent to judge that equipment.

Power Loss and Reset Output Behavior Needs Machine Specific Assessment

The product information also describes a power-loss or reset output that activates when the readout loses power or resets, with the stated purpose of stopping and locking the EDM machine. The scenario is easy to picture: the readout goes dark mid-cut while the electrode is still feeding down, and nothing on the display tells the operator where the cut has reached. A relay suits that job because its resting state is physical. Cut power to the coil and the contacts spring back to normal, so the circuit changes state without any software deciding to do it. Which way that change travels is settled by the pair in use. With the normally open pair wired, a de-energized relay leaves the circuit open; with the normally closed pair wired, the same power loss leaves it closed. If normal running depends on holding the relay in its active state, losing power flips both pairs at once, and only the machine's stop logic can say whether that reads as a stop command or as a lost signal. Trigger conditions, the recovery path after power returns, whether the machine latches the stop, and who clears it afterwards are all machine-side questions. Asking an EDM position readout supplier for the wiring diagram and contact rating before connecting anything is reasonable, and a competent person should assess the installation as work equipment in its own right. That is also where a design intention becomes a real outcome. Stopping and locking an EDM machine through a switched contact depends on the machine reacting to that contact in the expected way, on the contact surviving the current it switches, and on the recovery sequence being understood by whoever runs the machine after a power interruption. The readout side of the chain is documented; the machine side is verified on the machine.

Conclusion

Target depth lives in the readout layer: pulses counted, position scaled, comparison made, number shown. The relay output lives in the control layer: coil energized, contact pair changed, machine input triggered. The power-loss or reset output sits on that same control layer and uses the relay's resting state to react when the readout drops out. Read a specification with those layers in mind and short feature lines become much clearer, because you can see which part carries information, which part is a switch, and which part belongs to the machine and the person wiring it. The ES8A product information gathers the deep-position display, target depth and relay contact relationships in one place, which makes it a practical reference to read beside the machine's own wiring diagram.

FAQ

Q: What is the difference between target depth display and relay output on an EDM readout?

A: The target depth display belongs to the readout layer. It stores the depth value you enter, compares it with the live Z position coming from the scale, and shows where the electrode stands against that target — information for the operator. The relay output belongs to the control layer. When the comparison reaches the target, the readout changes a contact state in the machine's control circuit, and the machine's own logic decides what that change does. One layer informs, the other switches.

Q: How does a normally open or normally closed relay contact affect an EDM stop circuit?

A: It changes which circuit state counts as "stop." A normally open contact stays open until the relay is energized and then closes, so it suits a machine input that triggers a stop when a circuit closes. A normally closed contact stays closed until energization and then opens, so it suits an input that expects a closed loop and reads an opening as the stop signal. On the ES8A the two pairs share pin 6, so you wire one or the other depending on what the machine input expects.

Q: Does a power-loss or reset output turn an EDM readout into a safety-rated control system?

A: No. The described output is a functional switching behavior that can stop and lock the machine when the readout loses power or resets, and it is a useful layer of protection during a cut. A safety-rated control system involves redundant channels, monitored contacts, defined performance levels and documented validation of the whole arrangement, including the machine circuits and the installation. Those elements are assessed on the machine, not created by adding a relay output.

Sources / References

Relay Switch Circuit and Types of Relay Switching Circuits

Using Work Equipment Safely

Easson ES8A Three Axis Easson Digital Position Readout With Linear Scale

Previous
How Do EDM Operators Read the Deepest Electrode Position on a Readout?
Read More
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.