Easson optical linear encoders are designed for direct linear position measurement and are compatible with DRO (Digital Readout) systems. Correct installation is essential to ensure measurement accuracy, repeatability, and long-term reliability.
Although milling machines and lathe machines differ in structure, the basic installation principles are similar.
1. The travel length of the glass grating scale must be longer than the maximum travel of the machine, there should be at least 10mm clearance between the ends of the glass scale and the maximum travel of the machine as per the following figure shown.

2, To ensure the graduated glass scale to be installed is reliable, and to avoid any possibility of scale misalignment, the scale should be installed on machined flat surfaces of the machine wherever possible.
In the case where there are no machined flat surfaces available on the machine, machined flat Blocks or the stainless steel fillers should be used. Wherever possible the scale ends and the reader head should be installed on a flat surface.
3, If a lever dial indicator is used to align the scale, it is important to ensure that the angle between the dial Indicator lever tip and the surface measured must be less than 30'to avoid a cosine measurement Error. If a vertical dial indicator is used as per the following figures shown, it is important to ensure that the dial indicator is perpendicular to the measured surface to also avoid the cosine measurement error.

4, The following considerations must be taken to select the proper installation locations
(1) Scales should be installed on to a machined surface.

(2) The opening of the scale must not be installed as to be directly exposed to swarf, oil, Water, dust or other foreign products. Covers provided should be installed.

(3) In cases where machined flat surfaces are not available, an installation block or strip should be used to provide a flat datum for the installation. The installation strip must be as short as possible to provide a rigid datum.

(4) A clearance of at least 3.0mm between the scale and scale cover.

5. All the tapped screw holes must have at least 6 threads to allow the screw to be firmly secured into the tapped holes. For the screw that is needed to secure a heavy load, the tapped holes must have at least 8 threads. After tapping the holes must be deburred and cleaned.

6. All cables must be fixed, but allow for the maximum machine travel movements. Below are diagrams, recommending the minium radius that should be used for bending the scale cable.

7. Grounding / Earthing is very important for the noise immunity, the grounding resistance must be less than 1.0 ohm.
8. The horizontal and Vertical alignment measurement are taken at 20mm away from the scale ends as per following figure shown.

Installation standards & Requirements
1. Requirements for the mounting surface
a) If the scale mounting surfaces are not parallel to each other (i.e. As per shown in figure A and B), the parallelism of the two mounting surfaces must be less than 0.1mm.
b) If the mounting surfaces are perpendicular to each other. (I.e.As per shown in figure c), the squareness of these two mounting surfaces must be less than 0.1mm.

2. Scale Alignment
It is very important that the scale must be aligned parallel to the travel of the machine slide.
For scale travel less than 950mm, the maximum parallel error between the scale and the machine slide must be less than 0.1mm 0.15mm.
For scale travel longer than 950mm, the maximum alignment parallelism error must be less that 0.1mm.

3. Clearances between the reader head and scale body
(1) The clearance between the reader head and scale body must be kept between 0.8mm-1.5mm.
(2) The reader head must be less than 0.5mm parallel with the scale and can be set with feeler gauges to allow the reader head to move unrestricted along the scale.

Direction on Lathe Installation
When travelling towards the headstock the reading should be reduced. Cross slide towards the centre should be reduced.
Note! At all times to give the best protection the scale should be mounted with the rubber seals facing down.
Where extreme exposure to swarf, coolant, dirt and compressed air, are present, sheet metal cover guards that are supplied should be placed over the scale for maximum protection.
Between the scale and the reader head there is a black strip which helps to maintain the correct distance between the reader head and the scale. This should be removed after installation

Scale Reading Direction
Before fitting the scale insure that the reading direction is correct. To change the direction of the reading of the scale, turn the scale over. Generally the scale is reading in the correct direction with the label of the scale exposed.
Lathe Scale Installation
Before fitting the scale connect the "x" axis to the cross slide to allow the Diameter function to work.
Fixing the X Scale on a Milling Machine
One of the easiest ways to set up an X scale on a milling machine, if the side of the table is machined, is to clamp two parallels to the flat table surface that the table travels on and sit the Scale on the parallels.

Carefully drill and tap the holes to take the screws provided

When the scale is mounted then fix the reader head to the saddle, if necessary packing the head to insure that it is parallel and in line with the scales(The black packing between the reader head and scale allows for the correct clearance and holds the reader head parallel to the scale. The black packing part need to take off after finished the installaion.)

Mount the cover over the scale and dril and tap the holes to secure it to the table making sure that there is 3mm clearance between the cover and the scale

Mount the scale on the backing plate using the pre drilled holes, checking that the scale is parallel with the machine slide with a dial indicator

Attaching the"Y"Axis Scale. lf the surface is not machined mount the backing plate and use the grub screws to adjust the backing plate, checking with a dial indicator,until the scale is square and perpendicular to the machine slides.

Mount the bracket on the saddle to take the reader head making sure that the reader head is in line and parallel to the scale. Secure the cable making sure to leave enough free cable to allow for the travel of the slide.

After the scale is aligned to the axis, then drill and tap the scale to suit the bracket provided and mount the bracket insuring that the reader head is sitting correctly so that when the reade rhead is attached it will be square and parallel tothe scale.

Fitting the "Z" Axis
Before mounting the scale insure that it will read "+" as you wind the table down, increasing the distance from the table to the cutter.
The"z" axis scale should be installed on the side of the column insuring that the open side of the scale is away from direct swarf and coolant and that the traveis in the right direction "_" towards the spindle and "+"away from the spindle. (Fig.1)
The bracket is (Fig 2)mounted of the knee, and around the scale to allow for the cover(Fig .3)to protect the scale where excessive coolant & swart are present.


Fig.1
LATHE INSTALLATION
To install a readout on a lathe the following tips can be used. To mount the cross slide scale select a flat surface that is suitable and clear of the travelling parts of the lathe.
The scale should be mounted insuring that it is parallel and square to the slide,
When mounting the reader head if necessary pack the reader head so that it travels in line and square to the scale to avoid any damage to the scale.
Testing for parallel can be done by either a dial indicator or a precision level



The long itudinal scale should be mounted on the back of the lathe (Fig 1) with the open side of the scale facing down and must be parallel to the bed. The reader head is mounted to the saddle (Fig .2 & 3) via the brackets provided.
Some modification may be required for some lathes. Covers should be mounted over the slides as per Fig 4
Fig .1
Yes. Easson encoders support horizontal and vertical installation when properly aligned.
2. Do Easson encoders require periodic recalibration?
Normally no. However, inspection is recommended after machine maintenance or collision.
3. Is professional installation required?
Experienced technicians can install the encoder. For high-precision applications, professional installation is recommended.
Optical Linear Encoder FAQs
Why Is Correct Installation Important for a Linear Encoder