Name: | 2 Axis Digital Readout For Milling Machine | Keyword: | Digital Readout Unit |
---|---|---|---|
Application: | Milling, Lathe, Boring Machine | Languages: | 8 Choices |
Display Resolution: | 0.1µm, 0.5µm, 1µm, 5µm | Weight: | 2.5 Kgs |
Power Supply: | 110V - 220V | Output Signal: | TTL |
Packaging & Delivery
Single package size: 40x26x18 cm
Package Type: Carton box
Net weight: 2.5 kgs
Delivery:
Quantity | 1-10 | 11-50 | 51-100 | >100 |
Est. time ( days ) | 3 | 5 | 7 | 15 |
The ES-14 series is CE certified and is manufactured according to the TQM(Total Quality Management System). The
electronic boards comply with the RoHS standards.
Technical Specification
Model | ES-14 | ||
Axis number | 2 Axis | ||
Axis Display | 0.1 μm, 0.5 μm, 1 μm, 5 μm | ||
Signal Input | TTL | ||
Power Supply | 110 V / 220 V | ||
Net Weight (KGS) | 2.5 | ||
Maximum input |
2 MB Hz | ||
Operating temperature | 0℃ - 45℃ | ||
Storage temperature | -40℃ - 55℃ | ||
Relative humidity | ≤ 95% | ||
Inputs | 3 Optical Ruler | ||
EMC Standard |
IEC61000-4-2 / GB / T 17799-2 IEC61000-4-4 / GB / T 17799-4 IEC61000-4-5 / GB / T 17799-5 |
EMC Testing equipment
To ensure that all Easson DRO products meet the standard EMC specifications, we are equipped with a full set of EMC testing equipment, including an ESD immunity tester.
Linear power transformers have several advantages that make them a preferred choice for certain applications, especially where power quality and simplicity are important. Here are some key benefits:
1. Low noise;
2. Simple design;
3. Excellent Voltage Regulation
4. Low Electromagnetic interface(EMI)
5. Robustness and Durability
6. High Surge Tolerance
These characteristics make linear power transformers especially suitable for applications that require high reliability, minimal noise, and stable power delivery.
However, they are generally less efficient and larger than their switching counterparts, which can be a disadvantage in applications where size and energy efficiency are more critical.
So Easson will also replace the transformer type into Switching power supply from the year 2024.
Easson DRO have been to conforms to relevant standards for the electromagnetic compatibility ( EMC ) as the details below:
IEC61000-4-2 / GB / T 17799-2: Electrostatic discharge immunity ( Contact discharge 6000V, air discharge 8000V )
IEC61000-4-4 / GB / T 17799-4: Electrical fast transient burst immunity ( pulse amplitude 2000V )
IEC61000-4-5 / GB / T 17799-5: Lightning surge immunity ( Superrimposed pulse voltage peak 2000V )
Aging Testing Room
All Easson Digital Readout System need to do the aging test, using three axis signal generator counting, make sure all couting reading correctly, high temperature test and load test for 72 hours before QC procedure.
Products Description
Digital Readout System
Basic parameters in the ES-14 are included as below:
Centering (1/2) |
Metric / inches Display (mm / Inch) |
Absolute / incremental (ABS / INC) |
Power off Memory (30 subdatum) |
199 subdatum |
Reference Memory (REF) |
Build in Calculator |
Pitch Circle Diameter (PCD) |
Line Hole Positioning (LHOLE) |
Simple “R” Function |
Smooth “R” Function |
Linear Error Compensation |
Non Linear Error Compensation |
Axis Speed Display |
Radius / Diameter |
Connector interface
PIN | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
TTL Signal | --- | 0V | --- | GND | --- | A | 5V | B | R |
Cable | --- | Orange | --- | Ground | --- | Yellow |